COBTEL IDC Data Center
video
COBTEL IDC Data Center

COBTEL IDC Data Center

Compliant with ANS/EARS-310-D, IEC297-2, DN41491, PART1, DIN41494, PART7, GB/9520.16-2015 standards, compatible with ETS standard protection levels.

Send Inquiry
Add To Inquiry

Description

Product Description

Designed and developed to meet the requirements of modern data centers for green energy, emission reduction, modularity, and intelligent monitoring, this product is widely applied in various industries such as finance, government, telecommunications, energy, transportation, healthcare, education, and manufacturing for the construction, expansion, and upgrade of data centers. It effectively improves energy efficiency and achieves energy savings of up to 30%. The product features include top strong and weak power cable trays, enclosed track doors (remote control, card swipe, password, induction), fire skylights, fire interlocking systems (audiovisual alarm, smoke detection, temperature, and humidity detection), integrated indoor/outdoor temperature and humidity-controlled air conditioning, UPS, rack-mounted precision power distribution cabinets, dedicated data center cabinets including cabinet assembly components, enclosed cold aisles, environmental monitoring systems, and KVM.

 

Product Features

Modular installation, where the entire system is prefabricated in the modular form at the factory for convenient on-site installation.
Superior heat dissipation compared to single cabinet cooling efficiency, increasing the installation density of cabinet equipment and saving space in the data center.
The top cover opens under the force of gravity to provide gas fire protection in the cold aisle area, ensuring safety and reliability.
Separation of cold and hot air, preventing airflow disturbance and short circuits, resulting in high cooling efficiency and energy cost savings.
Comprehensive room management, dynamic management, energy efficiency analysis, robust security management, standard network management interface, precise battery management, and convenient maintenance and administration.

 

Technical Specifications

Product Characteristics
Channel Specifications (Width x Depth x Height) mm:
Single row: Lx(2200~2400)x(2000~2200)
(Excluding the height of the skylight when flipped) L<15m (including air conditioning)
Cabinet depth supports 1000mm, 1100mm, and 1200mm; cabinet height supports 2000mm and 2200mm.
Double row: Lx(3200~3600)x(2000~2200)
(Excluding the height of the skylight when flipped) L<15m (including air conditioning)
Cabinet depth supports 1000mm, 1100mm, and 1200mm; cabinet height supports 2000mm and 2200mm.
Enclosed aisle width supports 1200mm and 1800mm.
A number of single module cabinets: Single row: 324; Double row: 640.
Installation method:
Raised floor installation, can also be directly installed on a cement floor.
Reliability level: Tier II or above.
Power supply standard: 380/400/415Vac, 50/60Hz, 3Ph+N+PE.
System protection level: IP20.

 

Power Distribution System

UPS Input Voltage: 380/400/415Vac, 50/60Hz, 3Ph+N+PE
UPS Rated Capacity: 20~250kVA
UPS Configuration: N, N+1, 2N
UPS Input Power Factor: Integrated Modular UPS: ≥0.9, Rack-mounted Modular UPS: 1
UPS Overall Efficiency: ≥95%
Maintenance Method: Online hot-swappable maintenance
Battery Arrangement: Built-in or external
PDU Installation Method: Front/rear vertical installation in the cabinet
Power Supply Method for IT Cabinets: Mains power/diesel generator + mains power/diesel generator; UPS + UPS; UPS + mains power/diesel generator
Other: Class C lightning protection, 10-inch display screen, branch power distribution parameter monitoring
Certification: CCC

 

Cooling System

Air Conditioning Selection: Row-level air-cooling/chilled water, Room-level air-cooling/chilled water
Cooling Method: Air-cooling, chilled water
Power Supply Method for Air Conditioner Indoor and Outdoor Units: Separate power supply
Air Conditioning Installation Method: Indoor unit suspended overhead floor installation, outdoor unit installed on the flat cement ground
Compressor Type: Row-level: variable frequency compressor, Room-level: fixed frequency compressor
Fan Type: EC fan
Air Supply Method: Row-level: horizontal air supply, Room-level: downward air supply
Air Conditioning Indoor Unit Dimensions (Width x Depth x Height) mm: Air conditioning: 300×1200×2000, 600×1200×2000
Certification: CQC energy-saving

 

Monitoring and Management System

Functional Modules: Centralized management, access control management, video surveillance, asset management, battery monitoring
Access Methods: Web access via operation and maintenance platform, local 10-inch touchscreen, mobile app (optional)
Alarm Methods: WeChat alarm, local sound, and light alarm, SMS alarm, email alarm, telephone alarm
Certification: Software copyright, software testing report

 

Cabinet System

Dimension Specifications (Width x Depth x Height) mm: (600/800) x (1000/1100/1200) x (2000/2200)
Usable Space: 42U/47U
Certification: Seismic report, load-bearing report

Hot Tags: cobtel idc data center, suppliers, manufacturers, factory, wholesale, price, pricelist, quotation, bulk, cheap,best,price,quote,quotation,wholesale,factory,supplier,manufacturer,B2B,cheap,source,bulk,marketplace,OEM,quality,vendor,maker,producer,distributor,good,provider,moq,sample,China,wholesaler,seller,dealer,brand,guide