Cat7 cable supplier | Cat7 Patch Cord Manufacturer China

COBTEL PRECISION ELECTRONICS CO., LTD. · DONGGUAN, CHINA · SINCE 2006

Cat7 cable supplier

You need shielded cords that hold 10 gigabit with margin to spare. We build 25,000 patch cords a day, and a Fluke analyzer checks every single one before it ships. As a direct Cat7 cable supplier, we quote in 12 hours, sample in 5 days, and load your container in 7.

Request the current price list, a free sample kit, or a custom OEM spec. Wholesale buyers get factory rates with no trader margin. This Cat7 cable supplier signs the numbers into the quote, so nothing moves after you approve it.

20 yrsmanufacturing connectivity since 2006
25,000finished cords per day, single category line
100%electrical scan plus 2% Fluke channel test
265patents filed across connectivity products

What This Factory Builds for Wholesale Buyers

Cobtel Precision Electronics makes Cat7 patch cords in one dedicated category on the same campus in Wanjiang, Dongguan. Bare copper rod arrives, gets drawn, stranded, foil-wrapped pair by pair, braided, jacketed, crimped with gold-plated plugs, tested, and bagged under one roof. Plants in Hubei, Guizhou, and Vietnam back up the main line. When you buy from a direct Cat7 cable supplier, you talk to the team that runs the machines, and price changes need a reason, not a mood.

  • 26AWG, 28AWG, and 32AWG conductors in 100% bare copper
  • S/FTP double shield in stock, plus a slim U/FTP build for dense racks
  • CM, CMR, CMP, LSZH, and VW-1 jacket ratings for any install site
  • Cut lengths from 0.5 m to 60 m, plus custom cuts to your rack plan
  • 50-microinch gold-plated, three-prong RJ45 contacts on every plug
  • Seven standard colors with RAL matching for brand programs

What Arrives in Every Carton

Standard packing keeps buying simple. Each cord slides into its own PE bag, ten bags bundle per sleeve, and cartons cap at 12 kilograms so one installer can lift them safely. Every carton carries your PO number, model, lengths, and color in print, plus a QR code that opens the lot's Fluke report. Retail programs ship in e-commerce cartons with drop-test records on file. Custom packing follows your artwork from 1,000 pieces, and a photo of the packed pallet reaches you before the truck does.

Where These Cords Go to Work

A Cat7 channel runs 600 MHz and wraps every pair in its own foil under an overall braid, so it shrugs off the noise that kills ordinary cords. That makes it the pick for trading-floor racks, broadcast control rooms, and robot cells that sit beside variable-frequency drives. Data centers use it where 10 gigabit must run with margin, not on the limit line. Brands private-label the slim builds for gaming and streaming rigs that route behind consoles. Distributors in more than 40 countries resell these stock programs, and every one of them started with a sample box from this Cat7 cable supplier.

Cat7 Patch Cord Specifications, MOQ, and Lead Times

All five cords below stay in current production. As your Cat7 cable supplier, we publish MOQ and lead time in the open, so your purchase plan needs one email instead of a week of chasing.

ProductConductor and ShieldJacket and RatingMOQLead Time
Cat7 10-Gigabit High Speed Network Cable Assembly26/28AWG stranded bare copper, S/FTP (pair foil + braid)PVC VW-1 or LSZH, 600 MHz500 pcs9 days
High Speed Ethernet LAN Cable for Laptop28AWG stranded bare copper, S/FTPPVC CM, 600 MHz500 pcs8 days
Computer Network Cable with RJ45 Connectors32AWG stranded bare copper, U/FTP slimPVC CM or LSZH, 600 MHz1,000 pcs8 days
Cat7 Internet Network Cord26AWG stranded bare copper, S/FTPPVC CM, 600 MHz, 10GBASE-T500 pcs7 days
Durable PVC Patch Cord28AWG stranded bare copper, S/FTPPVC CM, 600 MHz1,000 pcs7 days

MOQ covers mixed lengths and mixed colors inside one model. Lead time starts after deposit and drawing sign-off. A Cat7 cable supplier who hides these two numbers plans to add them later, so we print them on the page and honor them in the contract.

Bare Copper or Nothing: Our Material Rule

Copper-clad aluminum kills links in two ways. Resistance climbs with distance, and PoE loads heat the aluminum core until the jacket yellows. We refuse the margin that CCA offers. Our bare copper arrives with a batch certificate, and our lab re-tests conductivity and elongation on every lot before it touches a spooler.

Cat7 earns its Class F badge with construction, not claims. Each of the four pairs gets its own foil wrap, a copper braid wraps all four, and the build must hold a return loss above 17 dB and a signal-to-noise ratio above 11 dB at 600 MHz. Those are the standard's own numbers, and our Fluke bench proves every batch crossed them. Connectors carry the same bar: Cat7 hardware must hold crosstalk attenuation of 60 dB or better at 600 MHz.

Ask any serious Cat7 cable supplier for conductor proof, then compare what comes back. We hand you the batch conductivity record, an EDX composition scan, a Fluke channel report for your exact build, and on request a cut sample under X-ray that shows solid copper center to edge. Solder-tip and scrape tests expose CCA in seconds, and we invite your third-party inspector to run them on our bench.

The same rule covers the plugs. Contacts carry 50 microinches of gold over nickel, housings use UL 94V-2 rated polycarbonate, and the three-prong contact design bites stranded conductors from both sides. The braid and foils fold back 360 degrees into the metallized plug backshell, so the shield path never breaks at the plug. Cords survive a 2,000-cycle bend and plug test on the bench sample before the lot releases.

Jacket choice follows the building, and we stock every rating. CM jackets suit ordinary office walls. CMR riser cable climbs between floors. CMP plenum cable runs through air channels where fire code demands it. LSZH wraps subway, studio, and data-hall projects where smoke must stay thin and low. Tell us the install site, and this Cat7 cable supplier locks the right rating into the spec sheet before you order a single meter.

Copper Gauge, Explained in One Pass

26AWG stranded copper is the workhorse of Cat7 patch cords: easy to route, friendly to crimp presses, and strong enough for full-length runs. 28AWG slim cords crowd into high-density racks and bend tight behind cabinets. The 32AWG U/FTP build patches the tightest panels of all, where forty cords share one manager. One rule holds across all of them: the longer the run and the heavier the PoE load, the thicker the copper you buy.

Wholesale Price Tiers

Volume moves price at this Cat7 cable supplier, and the ladder is public. Pick your band, and the quote you receive matches it to the cent.

500 – 4,999 pcs

  • Standard wholesale rate
  • 7-day lead time on stock builds
  • Free Fluke report per lot

5,000 – 19,999 pcs

  • About 8% off standard rate
  • Free OEM jacket printing
  • Dedicated production slot

20,000 – 49,999 pcs

  • About 14% off standard rate
  • L/C at sight accepted
  • Batch photos before shipment

50,000 pcs and up

  • About 22% off standard rate
  • Price locked for 45 days
  • Reserved line capacity each month

OEM, ODM, and OBM Built for Your Label

Custom programs start at 1,000 pieces for OEM. We ink-print your brand on the jacket, mold boots in your colors, and ship cords in private-label poly bags with your barcode. Deeper ODM work covers custom RAL jacket colors, custom carton design, and length sets matched to your rack drawings. OBM closes the loop for distributors: standard cords ship under the COBTEL brand in retail-ready bags with barcodes, no tooling, and 500-piece minimums per model. Sign an NDA on day one, and our engineers return drawings within 5 working days. The tooling for boots and stamps stays in our own mold shop, so a revision costs days, not a month. Every Cat7 cable supplier claims OEM service; we show the mold machines that produce it.

Three Orders That Show the Range

German Industrial-Automation OEM

An automation maker wired robot cells that run beside variable-frequency drives, so noise was the enemy. We supplied 60,000 S/FTP 26AWG cords with 360-degree shield termination and delivered in 22 days. Their commissioning crew logged zero EMI rejects across every cell, and the account now orders against a yearly frame agreement.

OEM · 60,000 pcs · 22 days · zero EMI rejects

Singapore Financial Data Center

A financial data center in Singapore needed 120,000 S/FTP 26AWG cords across seven halls, each lot proven before install. We ran third-party channel tests per lot, passed on the first submission, and closed the run in 30 days. The delivery schedule held to the day in all four weekly batches.

OEM · 120,000 pcs · 30 days · first-pass third-party test

Canadian Broadcast Systems Integrator

A broadcast integrator rebuilt two control rooms where racks sit tight and bends run sharp. We tooled a slim low-profile boot and supplied 40,000 28AWG S/FTP cords in 18 days. The cords passed their staging tests with headroom, and the integrator added a second studio the next quarter.

ODM · 40,000 pcs · 18 days · slim-boot ODM build

Three programs, three labels, one pattern: buyers keep this Cat7 cable supplier on the next tender list.

What Buyers Say After the First Container

"Quotes in 12 hours, cords in nine days, zero rejections in two years. COBTEL is the one Cat7 cable supplier our QC team never needs to audit twice."

Stefan L. · Purchasing Lead · Automation OEM, Germany

"The per-lot channel reports matched our own analyzer on every one of the 120,000 cords. Our board audits suppliers yearly, and this file was the shortest one to close."

Priya N. · Data-Center Program Manager · Singapore

"Their engineer tooled our slim boot in two weeks and answered my WhatsApp on a Sunday. The cords bend where our old ones cracked."

Marc D. · Systems Integrator · Broadcast Studio Buildouts, Canada

Certifications on File

Every Cat7 cable supplier claims quality, so we hand you the paper instead. Copies of every certificate below reach your inbox the same day you ask.

ISO 9001:2015Quality management across all five plants
ISO 14001:2015Environmental system, audited yearly
IATF 16949Automotive process discipline since 2023
ULListed under file E508595
CEEMC directive conformity for EU buyers
RoHS 3.0Tested to EN IEC 63000
REACHSVHC screened against 240+ substances
CNAS L21456Accredited in-house lab, national-valid reports

Need GHMT, ETL, or third-party Class F channel evidence for a tender? Our lab team assembles the test pack in 5 working days and walks it through with your project manager.

Inside the Plants

Cobtel Precision Electronics runs five manufacturing centers: the Dongguan headquarters, Guangdong Quansheng, bases in Hubei and Guizhou, and the Vietnam plant that opened with our Hong Kong entity in 2025. More than 600 employees work across eight operating centers. The Dongguan campus opened its own industrial park in late 2021, with a 41,731 square meter headquarters building on a 21.18 mu site.

The depth of the shop floor decides what a Cat7 cable supplier can promise. We grind our own molds on mirror EDM machines to 0.01 mm precision, run 24 high-precision presses for contact stamping, and inject jackets and boots on 82 molding machines with 30 robotic arms. Four patch cord lines turn out 25,000 finished cords a day. Machines we designed ourselves insert contacts at 300 pieces per minute and sort defects with AI vision at 100% coverage.

Recognition followed the discipline. The state named us a National High-Tech Enterprise in 2016 and a national Little Giant in 2020, and Guangdong ranked us in its connector industry Top 100. We file 5% of sales into R&D each year, and 265 patents protect the product line. Six to seven of the world's and China's top ten structured cabling brands buy from our lines directly, and their audits keep our process honest. This is the factory floor behind every cord from this Cat7 cable supplier.

Digital systems run the same floor. ERP, MES, and WMS platforms track each lot from copper reel to sealed carton, and AGV carts move work between cells without idle handling. Workshop dashboards stream output live, and the digital management system links your order to a production plan the same day it lands. When an auditor asks for traceability, we pull the full record for a lot in minutes.

Why Buyers Switch to COBTEL: The Concrete Differences

Buyers who compare one Cat7 cable supplier against another usually grade the same ten things. Here is the scorecard, with no adjectives doing the work.

Decision FactorCOBTELTrading CompanyTypical Small Workshop
Price levelFactory rate, tiers published on this pageAdds 15 to 30% margin on top of a factoryLow quote, CCA copper often behind it
Quote speed12 working hours1 to 3 daysUnpredictable
MOQ500 pcs standard1,000 pcs or more500 pcs, quality varies by batch
Lead time7 to 12 days, printed in the contract15 to 25 days, two parties to blame10 days when the line is free
Copper proofBatch records, EDX scan, X-ray on requestPaper claimsRarely offered
Test reportsFluke PDF per lot, from our CNAS L21456 labTemplate reports at bestManual tester photos
CertificationsISO 9001, ISO 14001, IATF 16949, UL E508595, CE, RoHS, REACHCopies of someone else's certificatesOne or two, often lapsed
ToolingIn-house mold shop to 0.01 mmOutsourced, weeks per revisionStandard molds only
Capacity25,000 cords a day across five plantsWhatever the factory can spareOne line, peak-season queues
Payment safetyNamed beneficiary, WhatsApp-confirmed changesThird-party accountsPersonal accounts

The differences compress into six numbers a buyer can act on:

  • 12 working hours from inquiry to a priced sheet
  • 500-piece MOQ on standard models
  • 7-day lead time on stock builds
  • 2% Fluke channel AQL per lot, PDF report with your PO number
  • 2,000-cycle bend standard on bench samples
  • 45-day price lock from 50,000 pieces

That is the whole case for this Cat7 cable supplier: the paperwork of a big brand, the minimums of a flexible partner, and answers inside one working day.

Six Checks Before a Carton Ships

Quality control runs as a fixed sequence, not a slogan. Every lot passes the same six gates, and the records stay on file for five years.

  1. Copper incoming. Conductivity and elongation tests on every batch, logged against the mill certificate.
  2. Plug incoming. XRF sampling confirms 50 microinches of gold on contacts, and housings check against UL 94V-2.
  3. In-process cabling. Laser gauges watch pair twist, foil overlap, and braid coverage, and any drift stops the line.
  4. 100% electrical scan. Automated testers run wire map, continuity, and length on every single cord, not a sample.
  5. Fluke channel test. A 2% AQL per lot goes through Fluke channel testing, and the PDF report carries your PO number.
  6. Pre-shipment audit. Bench samples take a 2,000-cycle bend and plug test, then finished cartons pass a drop check.

When a buyer audits this Cat7 cable supplier, we open the QC room, the logbooks, and the Fluke units. Bring your checklist and your inspector; nothing here needs a script.

Trade Terms, Stated Once, in Full

  • MOQ: 500 pcs on standard S/FTP models, 1,000 pcs on the slim 32AWG build
  • Samples: 5 pcs free, courier collect, dispatched in 3 to 5 days
  • Payment: T/T 30% deposit and 70% before shipment; L/C at sight from 20,000 pcs
  • Incoterms: FOB Shenzhen and EXW Dongguan standard; DDP quoted on request
  • Lead time: 7 to 12 days after deposit on standard builds; 15 to 25 days for containers
  • OEM printing and private label from 1,000 pcs; artwork in 3 working days
  • Packaging: 1 pc per PE bag, custom cartons and barcodes welcome

Price lists from this Cat7 cable supplier stay valid for 30 days, and the contract repeats the MOQ and lead time from this page word for word.

Security note: pay only to the bank beneficiary Cobtel Precision Electronics Co., Ltd. We never ask for crypto, and we never change bank details by email alone. Message your sales contact on WhatsApp to confirm any change before you transfer.

From Inquiry to Container in Four Moves

The path from first email to loaded container follows four fixed moves, and each one has a clock on it.

  1. Inquiry to quote. Send lengths, AWG, shield, jacket, and quantity. A priced sheet lands in your inbox within 12 working hours.
  2. Sample. Five free cords ship in 3 to 5 days with a Fluke report for the exact build.
  3. Pilot. A 1,000-piece pilot run in 10 days qualifies the cords inside your own channel before you commit a container.
  4. Container. The full order completes in 15 to 25 days, with batch photos and test PDFs sent before the truck leaves.

Buyers who follow this path get predictable weeks, not promises. This Cat7 cable supplier keeps the same clocks in peak season, because the lines and the tooling sit under our own roof.

Repeat buyers move to standing rhythms. A blanket PO with monthly releases locks your price and holds line capacity. Safety stock of two to four weeks per SKU sits in our warehouse and ships within 48 hours of your release order. A quarterly review packs your claim rate, test data, and volume forecast onto one page. The result reads like a supply department you never had to hire.

Get Your Cat7 Quote Today

Tell us your lengths, AWG, shield type, jacket rating, and quantity. A priced sheet reaches you within 12 working hours, and free samples ship the same week. This Cat7 cable supplier answers on email and WhatsApp seven days a week, in your timezone.

  • Email: info@cobtel.com
  • WhatsApp: +86 138 2911 7062
  • Factory: Wanjiang, Dongguan, Guangdong, China
  • Factory visits welcome, Monday to Saturday, by appointment

Prefer to see it first? Book a factory tour, walk the QC room, and watch a Fluke test run on your own sample before you sign anything.

Samples carry no MOQ. Quotes stay valid for 30 days. Ask for the current price list and the latest Fluke sample report in the same reply.

Cat7 Sourcing Questions, Answered

What is your MOQ for Cat7 patch cords?

Our MOQ is 500 pieces for standard S/FTP models. The slim 32AWG build starts at 1,000 pieces. You can mix lengths and colors within one model, and the mix still counts as a single MOQ.


How fast can you deliver a wholesale order?

Stock builds of 500 to 20,000 pieces ship in 7 days after your deposit and drawing sign-off. Custom colors and mixed models need 10 to 15 days. A full container of 50,000 pieces or more loads in 15 to 25 days.


How do you prove the conductors are pure copper?

We run a conductivity and elongation test on every copper batch, plus an EDX composition scan, and keep the records on file. Each lot ships with a Fluke test report in PDF that carries your PO number. On request we cut a sample cord and X-ray the conductor, which exposes CCA wire in seconds.


Why do your Cat7 cords end in RJ45 when the standard mentions GG45?

Class F added GG45 to the standard, and IEC 60603-7-7 defines the dedicated interface. In practice, buyers keep RJ45 so cords stay plug-and-play with Cat6A, Cat6, and Cat5e ports. Every Cat7 cable supplier in this market terminates on RJ45 by default, and our cords pass Class F channel limits on the Fluke bench. GG45-terminated cords run as a project order.


Is Cat7 worth the premium over Cat6A?

Cat7 widens the channel to 600 MHz and wraps every pair in foil plus an overall braid. That S/FTP construction pushes alien crosstalk close to zero, so 10 gigabit runs with a wide margin in factories, studios, and dense data halls. Standard offices stay fine on Cat6A; harsh sites earn back the Cat7 premium.


Do shielded Cat7 cords need grounding?

The braid and pair foils terminate 360 degrees into the metallized plug backshell, and the shield path completes through grounded equipment ports. Patch cords on a grounded rack need no extra work. We test shield continuity on every sampled lot.


Do you offer OEM printing and private label?

Yes, OEM starts at 1,000 pieces. We ink-print your brand on the jacket, mold boots in your colors, and pack cords in private-label poly bags and cartons. Our engineers return print-ready artwork within 3 working days of your files.


Can I get free samples before I commit?

We send 5 sample cords free of charge and you cover the courier fee. Samples leave the factory in 3 to 5 days with a Fluke report for the exact build you asked for. Most buyers test the sample, confirm the PO, and keep the same spec in production.


Which certifications do your Cat7 cords hold?

The factory runs ISO 9001, ISO 14001, and IATF 16949 systems, and our cords carry CE, RoHS, and REACH compliance. Our UL listing sits under file E508595. Our in-house lab is CNAS accredited under number L21456, and third-party Class F channel reports come from GHMT and ETL on request.


Can one purchase order mix different Cat7 models?

Yes, one PO can combine S/FTP builds and the slim U/FTP model in any lengths and colors. Each model meets its own MOQ and ships under one invoice. You can even consolidate copper cords with our fiber patch cords in the same container.

Cat 7 twisted pair cables are divided into F and FA types. The F type operates at a frequency of 600 MHz, while the FA type operates at 620 MHz.
Cat 7 cables are primarily designed to support the demands of 10-gigabit Ethernet technology. Unlike unshielded twisted pair (UTP) cables, they are shielded 
twisted pair cables(STP). Consequently, they offer a comprehensive attenuation-to-crosstalk ratio of at least 500 MHz and an overall bandwidth of 600 MHz, which is more than double that of Cat 6 and Cat 6a cables. The transfer rate can reach up to 10 Gbps. In Cat 7 cables, each pair of wires is individually shielded, and all four pairs are wrapped together in an overall shield. This additional layer makes the diameter of Cat 7 cables larger than their predecessors. A key distinction lies in the ability of its connecting hardware: Cat 7 systems require connectors that provide a minimum of 60 dB of crosstalk attenuation at 600 MHz.
Compared to 
Cat 5e cables, and Cat 6 cables, Cat 7 cables offer significantly higher transmission bandwidth, with a minimum of 600 MHz. The Cat 7 cabling system is not backward-compatible with the RJ-45 connectors used in previous cabling systems.

 

A. Key developments in Cat 7 cables include:

  1. On June 29, 1999, at a meeting of ISO/IEC, JTCL/SC, and 25/WG3 in Berlin, Germany, 69 experts unanimously agreed to incorporate the Cat 7 connector solution, GG45-GP45, proposed by Nexans, into the international wiring standard ISO/IEC 11801.
  2. On August 27, 2001, at an ISO/IEC meeting in Germany, Nexans suggested that IEC60603-7-7 be finalized as the Cat 7 interface standard.
  3. Cat 7 cables typically use a skin-foam-skin single-wire structure.
  4. The outer diameter of the copper conductor in Cat 7 cables is chosen to be around 22AWG (some advocate for 19AWG).
  5. The bandwidth of Cat 7 cables is 600 MHz.
  6. The test frequency range for network analyzers is 0.064~1000 MHz.
  7. The permanent link distance is 90 meters.
  8. The insertion loss is approximately 2 dB (with a 3-meter reduction for horizontal cables or a 2-meter patch cord).
  9. The near-end crosstalk loss is between 5.1 and 7 dB.
  10. The ACR is -1.9 dB.
  11. The far-end crosstalk is 45.3 dB.
  12. The return loss is 8.4 dB.
  13. The delay is 45 ms.
  14. The delay skew is 44 ms.
  15. The DC loop resistance is 34 Ω.
  16. The coupling attenuation is 64.4 dB.

 

B. Interface

When drafting the Cat 7 standard, there were significant changes in network interfaces. Eight types of connectors were proposed: two "RJ" style and six "non-RJ" style. In January 1999, the ISO technical committee decided to select one "RJ" and one "non-RJ" style interfaces for further study. At the ISO/IEC JTC1/SC 25/WG3 working group meeting in August 2001, ISO once again confirmed the Cat 7 standard would include both "RJ-type" and "non-RJ-type" interfaces.

C. Cat 7 Twisted Pair Cable Structure

The structure of Cat 7 twisted pair cables is shown in Table 1.
Table 1: Cat 7 Twisted Pair Cable Structure
STP SFTP
Conductor 22/23AWG Solid Copper 22/23AWG Solid Copper
Insulation Polyethylene Polyethylene
Shielding Aluminum Foil Individual Shield Aluminum Foil Individual Shield + Copper Wire Braided Overall Shield
Drain Wire 7/0.2mm None
Sheath PVC/LSZH PVC/LSZH

  1. Physical Structure of Cat 7 Twisted Pair Cable

001.webp

002.webp

003.webp

Figure 1.(The physical structure of Cat 7 twisted pair cables)

D. Operational Frequency Bandwidth of Cat 7 Twisted Pair Cable

The operational frequency bandwidth of Cat 7 twisted pair cables ranges from 1 to 600 MHz (universal standard) and 1 to 1000 MHz.

E. Physical Characteristics of Cat 7 Twisted Pair Cable

□ Transmission speed (NVP): 79%.
□ Maximum Relative Capacitance: 5.6 nF/100m.
□ Maximum DC Resistance Unbalance: 5%.
□ Maximum Propagation Delay Skew: 30 ns/100m.
□ Maximum Propagation Delay: 536 ns/100m @ 100 MHz.
□ Rated Voltage: 60 Vrms.
□ Maximum Tensile Load: 80 N.
□ Operating Temperature: -20°C to +60°C.
□ Storage Temperature: -5°C to +50°C.
□ Flame Retardancy: Passes IEC 332-1 (FRRVC & LSOH sheath).

F. Electrical Performance Parameters of Cat 7 Twisted Pair Cable

The electrical performance parameters of Category 7 twisted pair cables are listed in Table 3.

Table 3: the electrical performance parameters table for Cat7 twisted-pair cables

 

Frequency(MHz) Near-End Crosstalk (NEXT) (dB/100m) minimum/worst/standard value ≥ Attenuation (dB/100m) ≤ Return Loss (dB) minimum/worst/standard value ≥ Signal-to-Noise Ratio (SNR) (dB/100m) minimum/worst/standard value ≥
1 90.0/100.0/80.0 2.0 20.0/23.0/20.0 88.0/98.0/80.0
4 90.0/100.0/80.0 3.6 23.0/26.0/23.0 86.4/96.0/76.4
10 90.0/100.0/80.0 5.7 25.0/28.0/25.0 84.3/94.0/74.3
16 90.0/100.0/80.0 7.2 25.0/28.0/25.0 83.3/92.0/72.8
20 90.0/100.0/80.0 8.1 25.0/28.0/25.0 82.5/91.0/71.9
31.25 90.0/100.0/80.0 10.1 23.6/26.0/23.6 80.0/90.0/69.9
62.5 90.0/100.0/75.5 14.5 21.5/24.0/21.5 76.0/85.0/61.0
100 90.0/100.0/72.4 18.5 20.1/23.0/20.1 72.5/75.0/53.9
200 90.0/100.0/67.9 26.8 18.0/23.0/18.0 65.0/70.0/41.1
250 95.0/90.0/66.5 30.2 17.3/23.0/17.3 50.0/58.0/36.3
300 95.0/90.0/65.3 33.3 17.3/23.0/17.3 59.0/55.0/32.0
600 80.0/90.0/60.8 48.9 17.3/20.0/17.3 32.0/50.0/11.9
Frequency(MHz) Equal-Level Far-End Crosstalk (ELFEXT) (dB/100m) guaranteed/typical/standard value ≥ Power Sum Near-End Crosstalk (PSNEXT) (dB/100m) minimum/worst/standard value ≥ Power Sum Attenuation to Crosstalk Ratio (PSACR) (dB/100m) minimum/worst/standard value ≥ Power Sum Equal-Level Far-End Crosstalk (PSELFEXT) (dB/100m) minimum/worst/standard value ≥
1 85.0/90.0/80.0 87.0/97.0/77.0 85.0/95.0/75.0 82.0/87.0/77.0
4 85.0/90.0/80.0 87.0/97.0/77.0 83.4/93.0/73.4 82.0/87.0/77.0
10 79.0/90.0/74.0 87.0/97.0/77.0 81.3/91.0/71.3 76.0/87.0/71.0
16 74.9/90.0/69.9 87.0/97.0/77.0 80.3/89.0/69.8 71.9/87.0/66.9
20 73.0/90.0/68.0 87.0/97.0/77.0 79.5/88.0/68.9 70.0/87.0/65.0
31.25 69.1/90.0/64.1 87.0/97.0/77.0 77.0/87.0/66.9 66.1/87.0/61.1
62.5 63.1/85.0/58.1 80.0/97.0/72.5 73.0/82.0/58.0 60.1/82.0/55.1
100 59.0/80.0/54.0 87.0/97.0/69.4 69.5/72.0/50.9 56.0/77.0/51.0
200 53.0/75.0/78.0 87.0/97.0/64.9 62.0/67.0/38.1 50.0/72.0/45.0
250 51.0/70.0/46.0 92.0/87.0/63.5 47.0/55.0/33.3 48.0/67.0/43.0
300 49.5/66.0/44.5 92.0/87.0/63.3 56.0/52.0/29.0 46.5/63.0/41.5
600 43.4/60.0/38.4 77.0/87.0/57.8 29.0/47.0/8.9 40.4/57.0/35.4

 

 

 

Shopping Bags